• Skip to primary navigation
  • Skip to main content

PMI

  • Home
  • Products
  • Library
    • Videos
      • All
      • Bolt Quality Tests
      • Promotional Videos
      • Support Videos
      • Power Quality Decoded
    • White Papers
      • All
      • Artificial Intelligence
      • Case Studies
      • Communications
        • All Communications
        • Cellular Communications
        • General Communications
      • Distributed Generation
      • IEEE Standards
      • Power Quality
        • All Power Quality
        • Analyzing Waveforms
        • Flicker
        • PQ Data Analysis
        • PQ Theory
      • Products
        • All Products
        • Boomerang
        • Boomerang SCADA
        • Box Recorder
        • Canvass
        • Eagle
        • Flex CT
        • Guardian
        • Merlin™
        • Meter Sockets
        • PQ Canvass
        • ProVision
        • Revolution
        • TLAR
        • Using PMI Recorders
      • Voltage
        • All Voltage
        • CVR
        • Voltage Sag
        • Voltage Unbalance
      • Harmonics
  • Training
    • All
    • PDH Eligible Classes
    • On-Site Training
    • Live Webinars
  • Support
  • Our Company
    • About
    • Contact
    • Join Our Team!
    • Receive our Newsletter
    • PQ Resources
    • Power Quality Solutions
  • Account
  • Cart - 0 items
PMI's Boomerang Pole Mount

Boomerang Pole Mount Voltage and Current Monitor

$1,775.00 – $2,438.00Price range: $1,775.00 through $2,438.00

Please call +1 (800) 296-4120 for International Pricing

The PMI Boomerang Pole Mount Voltage and Current Meter is a compact monitoring solution designed for electric utility distribution systems. Engineered for pole-mounted deployment, it provides reliable voltage and current monitoring for overhead distribution applications while enabling utilities to improve visibility into feeder performance and system conditions.

Built for fast installation and dependable field operation, the Boomerang Pole Mount captures critical electrical measurements directly from the distribution line. Its compact form factor and rugged construction make it well suited for long-term deployment in demanding outdoor environments. By providing continuous monitoring of voltage and current conditions, utilities can identify abnormalities faster, improve operational awareness, and support more informed maintenance and troubleshooting decisions.

Combined with PMI’s PQ Canvass data analysis software, the Boomerang Pole Mount helps utilities streamline data collection and gain actionable insight into distribution system behavior. The result is improved efficiency, enhanced situational awareness, and more effective monitoring of overhead utility infrastructure.

 

Get Started Here


  • Clear

Have a PQ Question? Ask Merlin™ — Free

Send it to askmerlin@powermonitors.com or text (540) 383-3144

  • Features and Benefits
  • Specs
  • Software
  • Downloads
  • White Papers
  • FAQ

Features and Benefits

The Boomerang Pole Mount Voltage and Current Meter is designed to provide utilities with improved visibility into overhead distribution system performance through reliable, real-time field monitoring. Installed directly on utility poles, the device continuously captures voltage, current, power, frequency, and other critical operating data, enabling utilities to identify developing issues before they escalate into larger operational problems. One-second values and user-defined averages provide detailed system insight while supporting both operational awareness and long-term analysis.

Configurable voltage, current, and power thresholds allow utilities to tailor monitoring parameters to specific feeder conditions and operational requirements. Instant alerts can automatically send email or text message alerts for threshold exceedances, outages, or other abnormal events, helping crews respond quickly and reduce downtime. Simultaneously comparing real-time voltage, current, and power measurements from multiple locations enables utilities to identify correlations across a distribution system and better understand feeder behavior under varying load conditions.

Its low-profile, unobtrusive form factor supports deployment in virtually any pole-mounted location while minimizing installation complexity and visual impact. The Boomerang Pole Mount is also optimized for low-cost telemetry data plans, helping utilities reduce communications costs while maintaining continuous system visibility.

Integrated DNP3 functionality supports seamless SCADA integration through TCP or UDP cellular connections. Flexible unsolicited report-by-exception triggers allow the device to work effectively with CVR and DMS systems, while analog DNP3 points provide access to RMS voltage, current, power, frequency, and modem signal strength data.

Because PMI’s data analysis software is browser-based, no software downloads are required. Utilities can easily manage user accounts, configure preferences, and set up distribution lists while securely accessing monitoring data from virtually anywhere.

Specs

Voltage
Input range 80-300V RMS
Accuracy 0.50%
Resolution 0.1V
Current
w/ TLAR-S probes 20, 200A
w/ Flex CTs 100, 1000, 5000A
Accuracy 1%
Power
Accuracy 1%
Communication
Standard LTE cell modem
Environmental
Temperature 
Range  -22°F to 130ºF, -30ºC to 54.44ºC
Physical Dimensions
Size 6.5”L x 6.5”W x 4.25”H
Weight 3.6 lbs
Case NEMA 4X

Software

Expand the Boomerang’s Data Analysis Capabilities

PQ Canvass Logo

PQ Canvass

PQ Canvass is the premiere way to view and analyze power quality data.
This cloud-based system is a powerful platform to collect, analyze, and
get alerts from field devices connected through LTE cell, WiFi, or Ethernet.


CLICK HERE TO LEARN MORE ABOUT PQ CANVASS →


Merlin Logo

Merlin™

Merlin™ is PQ Canvass’ AI-assisted power quality analysis tool.
Merlin analyzes PQ recordings, automatically identifies issues,
applies standards-based checks, and surfaces clear results in minutes.


CLICK HERE TO LEARN MORE ABOUT MERLIN →


Merlin

Have a PQ Question? Ask Merlin™ — Free

Send it to askmerlin@powermonitors.com or text (540) 383-3144

Downloads

Specification Sheet

  • Boomerang Spec Sheet

Boomerang Manual

Boomerang Manual

 

White Papers

  • Canvass Multiburst
  • Using PMI Boomerangs with an RTAC
  • Viewing PQ Canvass Boomerang Data in ProVision
  • Holdoff and Aggregation with Canvass Alerts
  • DNP3 Point Map 2.0 Update
  • Case Study: Spotting Pump Failure with a Boomerang and Canvass
  • Managing Outages with Canvass and PQ Canvass
  • Separating Voltage Sags from Steady State Voltage Readings
  • Advanced E-Mail Alerts in Canvass
  • Alert Level Programming and Analysis
  • Sharing Cloud Based Data
  • Real-Time Voltage Interruption Detection and Alerting
  • Cybersecurity and Cell Communications with the Guardian, Revolution, & Boomerang
  • Boomerang Configuration for SCADA Systems
  • Hardware for Power Quality and Distribution Monitoring
  • Seven Common Utility Distribution Challenges: How the Boomerang and Canvass Can Help
  • Advanced Daily Profile Analysis with Canvass
  • End-to-End Boomerang Cybersecurity
  • Getting Started with the NMS
  • Getting Started with the Pole Mount Boomerang
  • Getting Started with the 3-Phase Boomerang
  • Voltage Optimization with the Boomerang and Canvass
  • Types of Boomerang Units
  • Networking the Ethernet Boomerang
  • Detecting Recloser Events with Boomerang Monitors
  • Boomerang DNP3 Point Map 2.0
  • Using Loss of Periodic Load to Trigger Email Alerts
  • UDP vs TCP on a Cellular Network
  • Boomerang Networking Options for SCADA and Canvass
  • Email Alerts with Canvass
  • NMS Security
  • Conservation Voltage Reduction with the Boomerang
  • Boomerang Burst Mode Operation
  • Introduction to PMI Network Management Software
  • NMS Installation
  • Conservation Voltage Reduction During Peak Loading Times
  • Voltage Unbalance with Single Phase Boomerangs in Canvass

FAQ

Does the Boomerang Pole Mount work with SCADA?

Yes. It provides a full DNP3 interface over TCP or UDP cellular connections, with analog points for RMS voltage, current, power, frequency, and modem signal strength, plus unsolicited report-by-exception and polled modes.

Can the Boomerang be used for CVR?

Yes. The DNP3 interface is optimized for demand management and conservation voltage reduction, with configurable voltage, current, and power thresholds and flexible report-by-exception triggers that work with CVR and DMS systems.

Does the Boomerang store data on the device?

No. Values are captured every second and forwarded to the cloud every few minutes. Nothing is stored on the device and no download operation is required.

What communication options are available?

Cellular LTE with an external antenna or Ethernet, non-PoE, powered from AC .

What current ranges does the Boomerang measure?

20 A and 200 A with TLAR-S probes, or 100 A, 1,000 A, and 5,000 A with Flex CTs.

How accurate is the Boomerang?

Voltage is accurate to 0.50% across an 80–300 V RMS input range with 0.1 V resolution. Current and power are accurate to 1%.

Where can the Boomerang Pole Mount be installed?

It’s built for pole-mounted outdoor deployment in a NEMA 4X enclosure, at 6.5″ x 6.5″ x 4.25″ and 3.6 lbs, for applications like voltage regulator monitoring, capacitor bank measurement, and end-of-line monitoring.

Related products

  • PMI's Boomerang 2S Socket Recorder.

    Boomerang 2S

    view more
  • Boomerang 3 Phase

    Boomerang 3 Phase

    view more

Have a PQ question? Ask Merlin™ — free. Send it to askmerlin@powermonitors.com or text (540) 383-3144.

Power Monitors, Inc. — Tools you Need. People you Trust.

Power Monitors, Inc. is an industry-leading product design and manufacturing firm based in Mt. Crawford, Virginia. PMI® strives to solve power quality problems by listening to our customers and working with them to design and manufacture products. Total customer satisfaction is the primary goal of all PMI® staff.

24/7 Tech Support 800.296.4120

Resources

  • White Papers
  • Videos
  • Training
  • Live Webinars
  • PQ Resources
  • Support

Company

  • About Us
  • Contact
  • Careers
  • Newsletter
  • Product Registration
  • Terms & Conditions
800 N Main St, Mt Crawford, VA 22841 | Toll Free 800.296.4120 | Fax 540.432.9430
© 2026 Power Monitors, Inc.