Interharmonics occur when a signal is present in a power system where the frequency is not an integer multiple of the 60 Hz line frequency. These can be generated from…
Voltage
Voltage Imbalance and Its Impact on Waveform Distortion
Voltage imbalance, also referred to as voltage unbalance, is an important power quality issue that can lead to significant operational problems in customer equipment. It occurs when the magnitudes or…
Voltage Regulation in PQ Canvass
PQ Canvass is a web-based power quality analysis software developed by Power Monitors Inc. It combines the foundational elements of Canvass with the features of ProVision, providing a set of…
Riding Through Voltage Sags with the IEEE 1668 Standard
Voltage sags are the most common power quality issue, and also the most costly for industrial power users. It's not practical for a utility to eliminate all sags, so industrial…
Analyzing Portable Power Station Inverter Power Quality
An engineer at PMI purchased a portable power station and wanted to verify the quality of the inverter before attaching sensitive electronics. The steps used to quantify the output quality…
Interharmonic Analysis with Python
Traditional harmonic analysis in electrical systems has revolved around looking at the spectral content on, well, the magnitudes of harmonic frequency components. The IEEE 519 specification provides guidelines for measuring…
Canvass Multiburst
MultiBurst is a feature of Canvass which provides a secondary user interface for easily requesting and receiving real-time data from multiple devices at the same time. This allows for quick,…
Introduction to Voltage Transients
Transients due to nearby lightning or switching events can cause degradation or failure of almost any electrical equipment. Impulsive transients can pass through transformer interwinding capacitance to appear on the…
Recommendations for Voltage Sags
Voltage sag is one of the most common power quality problems. The consequences for not troubleshooting a voltage sag complaint isn't the resulting damage that can be done to electrical…
Using PMI Boomerangs with an RTAC
Introduction In addition to PMI's cloud-based Canvass system compatibility, Boomerang distribution monitors including a DNP3 port for use in SCADA. Advanced distribution programs such as volt/VAR optimization, DER management, and…
CBEMA Graphs Revealed
The CBEMA (Computer Business Equipment Manufacturers Association) curve and the ITIC (Information Technology Industry Council) curve both refer to a similar method to visibly represent voltage events. A graph of…
Real-Time Voltage Interruption Detection and Alerting
Utility situational awareness is critical with today's high customer expectations, increased regulatory scrutiny, and reliance on stable AC power. Voltage interruption/outage detection is the most basic, and usually the most…