A loose neutral is not obvious to the naked eye but can lead to significant damage. The symptoms vary widely, and proper detection is essential to mitigation. This paper gives…
Guardian
Using PQ Canvass
PQ Canvass is an advanced cloud-based software application that enhances power quality analysis. PQ Canvass revolutionizes power monitoring with its comprehensive browser-based functionality, eliminating the need for additional software, and…
Recommendations for Voltage Sags
Voltage sag is one of the most common power quality problems. The consequences for not troubleshooting a voltage sag complaint isn't the resulting damage that can be done to electrical…
New ProVision Release for Handling Large PQ Recordings
With the introduction of the cell Guardian, 1 GB of memory in a PQ recorder is increasingly common. Although the resulting large files can provide a wealth of data, they…
THD Waveform Capture Triggering
The simplest waveform capture triggering is based on RMS voltage or current changes. While sufficient for voltage sags, recloser operations, etc., more complex events such as cap bank switches, narrow…
CBEMA Graphs Revealed
The CBEMA (Computer Business Equipment Manufacturers Association) curve and the ITIC (Information Technology Industry Council) curve both refer to a similar method to visibly represent voltage events. A graph of…
Wireless Power Quality
The time and cost of deploying PQ instrumentation only to return later in order to retrieve it (without the guarantee that the PQ anomaly has occurred) is often times exorbitant.…
Cybersecurity and Cell Communications with the Guardian, Revolution, & Boomerang
Cybersecurity is an important component for any electric utility network device. PMI devices such as the Cell Guardian, Revolution, and Boomerang (Figure 1) generate data from raw voltage and current…
Quantifying Residential Voltage Sags
Voltage sag complaints are one of the most common in residential applications. Despite complaints, many residential voltage sags are not actually troublesome, or caused by the utility. Quantifying sag events…
Power Quality Recorder Setup Basics (Part 2)
This whitepaper is a continuation of WP241 (Recorder Setup Basics). In part one the details and relative memory consumption of interval recording was discussed along with the associated controls for…
IEEE 519 Harmonics in Residential Locations
IEEE 519 specifies the measurement technique and limits for harmonics in a wide variety of locations, from transmission through distribution. For the first time, the 2014 edition also provides separate…
Cell, WiFi, and More with the New Cell Guardian Meter Socket Recorder
PMI has just introduced a major redesign of the Guardian meter socket power quality analyzer. This white paper will focus specifically on the new Cell Guardian recorder and cover the…