• Skip to primary navigation
  • Skip to main content

PMI

  • Home
  • Products
  • Library
    • Videos
      • All
      • Bolt Quality Tests
      • Promotional Videos
      • Support Videos
      • Power Quality Decoded
    • White Papers
      • All
      • Artificial Intelligence
      • Case Studies
      • Communications
        • All Communications
        • Cellular Communications
        • General Communications
      • Distributed Generation
      • IEEE Standards
      • Power Quality
        • All Power Quality
        • Analyzing Waveforms
        • Flicker
        • PQ Data Analysis
        • PQ Theory
      • Products
        • All Products
        • Boomerang
        • Boomerang SCADA
        • Box Recorder
        • Canvass
        • Eagle
        • Flex CT
        • Guardian
        • Merlin™
        • Meter Sockets
        • PQ Canvass
        • ProVision
        • Revolution
        • TLAR
        • Using PMI Recorders
      • Voltage
        • All Voltage
        • CVR
        • Voltage Sag
        • Voltage Unbalance
      • Harmonics
  • Training
    • All
    • PDH Eligible Classes
    • On-Site Training
    • Live Webinars
  • Support
  • Our Company
    • About
    • Contact
    • Join Our Team!
    • Receive our Newsletter
    • PQ Resources
    • Power Quality Solutions
  • Account
  • Cart - 0 items
PMI's TLAR-S Current Clamps.

TLAR-S Current Clamp – Bolt

$2,165.00

Please call +1 (800)296-4120 for International Pricing

The Bolt TLAR-S is a compact clamp-style current transformer built for installations where a standard clamp won’t fit — small enclosures, crowded panels, and confined mounting locations. It clamps around a conductor without direct electrical contact, so it goes in safely without interrupting service, and it holds high resolution at lower current levels where subtle load variation matters.

These are only compatible with the Bolt Power Quality Recorder. PMI sells separate TLAR-S sets for the Seeker+ and for other recorders.


Have a PQ Question? Ask Merlin™ — Free

Send it to askmerlin@powermonitors.com or text (540) 383-3144

  • Features & Benefits
  • Specs
  • White Papers
  • FAQ

Features & Benefits

Three Elements for Three Channels

The Bolt records three current channels, and this set supplies a clamp for each of the three phases — full three-phase coverage without the added cost and bulk of a fourth clamp. It’s the right fit for standard three-phase studies where neutral current isn’t part of the measurement.

Two Ranges in One Clamp

The TLAR-S measures 20 A and 200 A AC on an adjustable range, with a 200 A continuous operating limit. Accuracy is 1.5% of reading ±0.1 A on the 20 A scale and 1.5% of reading ±0.5 A on the 200 A scale, across a 40 Hz to 10 kHz frequency range. Phase shift stays at or below 3 degrees from 1–20 A, 2 degrees from 20–80 A, and 2.5 degrees from 80–200 A, which keeps power and power factor measurements dependable across the full load range rather than only at the top of the scale.

Because the 20 A scale holds the same percentage accuracy at low current, the clamp is well suited to lightly loaded circuits and residential feeders, where a 200 A-only probe would leave you reading noise.

Built for Enclosures That Are Already Full

The clamp accepts conductors up to .59 in (15 mm), with an enclosure measuring 2.36 x 1.38 x 0.67 in. Four-foot probe leads and a 9-inch output cable, both rated to 600 V, give enough reach to route around existing equipment without crowding the recorder.

That compact footprint matters just as much with three clamps. In a panel where a full-size clamp won’t close on a single conductor, fitting three of them side by side often isn’t possible at all — the TLAR-S makes three-channel measurement practical in spaces where it otherwise isn’t.

Safe Installation, No Downtime

As a clamp-style current transformer, the TLAR-S measures without direct electrical contact and without breaking the circuit, so there is no shutdown to schedule and no customer interruption to coordinate. It is rated to IEC 61010-1, 600V CAT III, with IP40 probes, and operates from 14°F to 131°F (-10°C to 55°C) — suitable for both a short study and a permanent installation.

Specs

Electrical Specifications
Current Ranges 20A, 200A AC
Operating Limit 200A Continuous
Frequency Range 40 Hz to 10 kHz
Working Voltage 600 VAC max
Influence of conductor position in jaw 0.5% of reading at 50/60 Hz
Influence of adjacent conductor 1.5% of reading
Influence of frequency 40 Hz to 1 kHz: 3% of reading; 1 kHz to 10 kHz: 12% of reading
Phase Shift
1–20 A ≤3 degrees
20–80 A ≤2 degrees
80–200 A ≤2.5 degrees
Accuracy
20A scale 1 to 20 A: 1.5% of reading ±0.1 A
200A scale 1.5% of reading ±0.5 A
Safety
Rating IEC 61010-1, 600V CAT III
PMI Recorder Capability
Compatibility Bolt Power Quality Recorder only. Adjustable 20A / 200A range.
Environmental
Operating Temp 14°F to 131°F, -10°C to 55°C
Case Protection Probes – IP40
Physical Dimensions
Maximum Conductor Size .59 in (15 mm)
Probes 5.00 x 1.67 x 0.93 in
Probe Leads 4 ft, 600V rating
Output Cable 9 in, 600V rating
# of Elements 3
Weight < 1.00 lb

White Papers

Measuring Current: Best Practices

Optimizing Current Resolution Using TLARs or Flex CTs

Using PMI’s TLAR and TLAR-S Clamp-Style Current Transformers

FAQ

Which recorders does the Bolt TLAR-S work with? +

The Bolt Power Quality Recorder only. PMI sells separate TLAR-S sets for the Seeker+ and for other recorders.

How many clamps come in the set? +

Three, matching the Bolt’s three-channel measurement.

What current ranges does it measure? +

20 A and 200 A AC on an adjustable range, with a 200 A continuous operating limit. Accuracy is 1.5% of reading ±0.1 A on the 20 A scale and 1.5% of reading ±0.5 A on the 200 A scale.

What size conductor does it fit? +

Conductors up to .59 in (15 mm) with 4 ft probe leads and a 9 in output cable, both rated to 600 V.

Do I need to shut down the circuit to install it? +

No. The clamp-style design measures without direct electrical contact and without breaking the circuit, so there is no shutdown to schedule and no customer interruption to coordinate.

Can it be left installed permanently? +

Yes. It is rated to IEC 61010-1, 600V CAT III, with IP40 probes, and operates from 14°F to 131°F (-10°C to 55°C), which suits both short-term studies and permanent deployment.

Related products

  • PMI's TLAR Current Clamp

    TLAR Current Clamp- Bolt

    view more
  • Image: Bolt power quality recorder

    Bolt™ Compact Power Quality Recorder

    view more
  • Bolt Hard Case.

    Hard Carrying Case – Bolt

    view more

Have a PQ question? Ask Merlin™ — free. Send it to askmerlin@powermonitors.com or text (540) 383-3144.

Power Monitors, Inc. — Tools you Need. People you Trust.

Power Monitors, Inc. is an industry-leading product design and manufacturing firm based in Mt. Crawford, Virginia. PMI® strives to solve power quality problems by listening to our customers and working with them to design and manufacture products. Total customer satisfaction is the primary goal of all PMI® staff.

24/7 Tech Support 800.296.4120

Resources

  • White Papers
  • Videos
  • Training
  • Live Webinars
  • PQ Resources
  • Support

Company

  • About Us
  • Contact
  • Careers
  • Newsletter
  • Product Registration
  • Terms & Conditions
800 N Main St, Mt Crawford, VA 22841 | Toll Free 800.296.4120 | Fax 540.432.9430
© 2026 Power Monitors, Inc.