• Skip to primary navigation
  • Skip to main content

PMI

  • Home
  • Products
  • Library
    • Videos
      • All
      • Bolt Quality Tests
      • Promotional Videos
      • Support Videos
      • Power Quality Decoded
    • White Papers
      • All
      • Artificial Intelligence
      • Case Studies
      • Communications
        • All Communications
        • Cellular Communications
        • General Communications
      • Distributed Generation
      • IEEE Standards
      • Power Quality
        • All Power Quality
        • Analyzing Waveforms
        • Flicker
        • PQ Data Analysis
        • PQ Theory
      • Products
        • All Products
        • Boomerang
        • Boomerang SCADA
        • Box Recorder
        • Canvass
        • Eagle
        • Flex CT
        • Guardian
        • Merlin™
        • Meter Sockets
        • PQ Canvass
        • ProVision
        • Revolution
        • TLAR
        • Using PMI Recorders
      • Voltage
        • All Voltage
        • CVR
        • Voltage Sag
        • Voltage Unbalance
      • Harmonics
  • Training
    • All
    • PDH Eligible Classes
    • On-Site Training
    • Live Webinars
  • Support
  • Our Company
    • About
    • Contact
    • Join Our Team!
    • Receive our Newsletter
    • PQ Resources
    • Power Quality Solutions
  • Account
  • Cart - 0 items
Boomerang 3-Phase Voltage and Current Monitor
boomerang-3-phase-portsboomerang-3-phase-lightboomerang-3-phase-1

Boomerang 3-Phase Voltage and Current Monitor

$1,545.00 – $2,139.00Price range: $1,545.00 through $2,139.00

Please call +1 (800)296-4120 for International Pricing

The Boomerang 3-Phase Voltage and Current Monitor is a compact, utility-focused solution designed for accurate monitoring of three-phase voltage conditions across distribution systems. Built for field deployment, the unit provides reliable data capture across a wide input range, supporting both standard installations and higher voltage environments when paired with PoE configurations. Its precise measurement capability ensures dependable visibility into voltage performance, enabling utilities and engineers to identify irregularities and maintain system stability.

With integrated communication options, including a standard LTE cell modem and optional Ethernet connectivity, the Boomerang 3-Phase supports flexible data access in both remote and networked environments. The Boomerang is engineered for durability, featuring a rugged NEMA 4X enclosure suitable for challenging environmental conditions. Its compact footprint and lightweight design allow for straightforward installation in a variety of field applications.

This combination of accuracy, communication flexibility, and environmental resilience makes the Boomerang 3-Phase a practical tool for ongoing voltage monitoring and operational awareness in modern power systems.

Please call us at 800-296-4120 to set up your product with an LTE cell data plan.

Get Started Here


  • Clear

Have a PQ Question? Ask Merlin™ — Free

Send it to askmerlin@powermonitors.com or text (540) 383-3144

  • Features & Benefits
  • Specs
  • Software
  • Downloads
  • White Papers
  • FAQ

Features & Benefits

The Boomerang 3-Phase Voltage and Current Monitor is pocket-sized and engineered to deliver consistent, high-accuracy voltage measurements across a broad operating range, allowing utilities to capture reliable data in both standard and elevated voltage environments. With a voltage input range of 80–300V RMS, extendable to 600V when utilizing PoE, the device adapts to diverse deployment scenarios without compromising measurement integrity. Its 0.50% voltage accuracy and fine 0.1V resolution provide the level of precision required for identifying subtle variations in system performance.

Optional power measurement capabilities, with an accuracy of 1%, expand the device’s usefulness by enabling additional insight into system behavior when needed. Communication flexibility is a key advantage, with a standard LTE cell modem supporting remote deployments and optional 10/100 Ethernet connectivity for integration into existing network infrastructure. The optional Power over Ethernet (PoE) interface removes the requirement to power from the channel 1 voltage input, and allows for voltage inputs up to 600V.

Designed for real-world field conditions, the Boomerang 3-Phase operates reliably across a wide temperature range from -22°F to 130°F. Its compact size and lightweight construction allow for efficient installation, while the weatherproof NEMA 4X enclosure provides protection against harsh environmental exposure. Together, these characteristics support dependable, long-term monitoring in utility and industrial applications.

Integrated DNP3 functionality supports seamless SCADA integration through TCP or UDP cellular connections. Flexible unsolicited report-by-exception triggers allow the device to work effectively with CVR and DMS systems, while analog and binary DNP3 points provide access to RMS voltage, current, power, frequency, and modem signal strength data.

Because PMI’s PQ Canvass data analysis software is browser-based, no software downloads are required. Utilities can easily manage user accounts, configure preferences, and set up distribution lists while securely accessing monitoring data from virtually anywhere.

Specs

Voltage
Input range 80-300V RMS (600V with PoE)
Accuracy 0.50%
Resolution 0.1V
Current
Measured Quantities 20A or 200A via TLAR-S clamps; 100A, 1000A, 5000A via other CT options
Power (Optional)
Accuracy 1%
Communication
Standard LTE cell modem
Options 10/100 Ethernet, PoE
Environmental
Temperature
 Range -22°F to 130°F, -30°C to 54.44°C
Physical Dimensions
Size 4.8”L x 3.35”W x 1.84”H
Weight < 1 lb
Case NEMA 4X

Software

Expand the Boomerang’s Data Analysis Capabilities

PQ Canvass Logo

PQ Canvass

Power Monitors’ PQ Canvass is the premiere way to view and analyze power quality data. Born from Canvass, our first generation cloud-based system, PQ Canvass is a powerful platform to collect, analyze, and get alerts from field devices connected through LTE cell, WiFi, or Ethernet. With connected devices and PQ Canvass come instant alerts, unlimited PQ data storage, and powerful reporting tools. Versatility is an important factor in PQ Canvass, allowing one to view data both in the office on a desktop, and on-the-go using a tablet or smartphone; the only requirement is internet access.

Learn more about PQ Canvass →


Merlin Logo

Merlin™

Merlin™ reads every waveform, chart, and compliance report in your PQ Canvass account—then writes the summary you’d spend hours creating. It identifies what matters, cites IEEE and ANSI standards, and explains each event in clear, human language. No guessing, no black box—just faster, defensible insight you can trust. With Merlin™, engineers spend less time digging through data and more time solving real power-quality problems.

Learn more about Merlin™ →

Merlin

Have a power quality question? Ask Merlin™ — free. Email askmerlin@powermonitors.com or text (540) 383-3144.

Downloads

Specification Sheet

  • Boomerang Spec Sheet

White Papers

  • Getting Started with the 3-Phase Boomerang
  • Boomerang Configuration for SCADA Systems
  • Using PMI Boomerangs with an RTAC
  • Types of Boomerang Units
  • Using Loss of Periodic Load to Trigger Email Alerts
  • Power Monitoring Hardware White Paper

FAQ

What voltage range does the Boomerang 3-Phase monitor support? +

The Boomerang 3-Phase supports an 80-300V RMS input range, extendable to 600V when paired with PoE configurations, covering both standard and elevated voltage environments.

What communication options does the Boomerang 3-Phase support? +

The Boomerang 3-Phase is equipped with cellular or Ethernet communication, allowing flexible connectivity for utility and distribution system deployments.

Does the Boomerang 3-Phase work with SCADA systems? +

Yes. The Boomerang 3-Phase can be configured for SCADA integration, including use with an RTAC, for utilities that need to incorporate monitoring data into their existing systems.

How accurate is the Boomerang 3-Phase? +

The Boomerang 3-Phase delivers 0.50% accuracy, providing reliable voltage and current measurements for distribution monitoring.

How do I ask a power quality question about my data? +

Email Merlin™ at askmerlin@powermonitors.com or text (540) 383-3144. Merlin™ is PMI’s AI assistant, trained on 425+ technical white papers.

Does the Boomerang 3-Phase support current measurement? +

Yes. When paired with TLAR-S clamps, the Boomerang 3-Phase measures 20A or 200A ranges; other compatible CT options extend measurement to 100A, 1000A, or 5000A ranges.

What environmental conditions can the Boomerang 3-Phase withstand? +

The Boomerang 3-Phase operates reliably from -22°F to 130°F (-30°C to 54.44°C) and is housed in a weatherproof NEMA 4X enclosure for protection against harsh field conditions.

Related products

  • Small Soft Carrying Case for PMI's Revolution.

    Soft Carrying Case

    view more

Have a PQ question? Ask Merlin™ — free. Send it to askmerlin@powermonitors.com or text (540) 383-3144.

Power Monitors, Inc. — Tools you Need. People you Trust.

Power Monitors, Inc. is an industry-leading product design and manufacturing firm based in Mt. Crawford, Virginia. PMI® strives to solve power quality problems by listening to our customers and working with them to design and manufacture products. Total customer satisfaction is the primary goal of all PMI® staff.

24/7 Tech Support 800.296.4120

Resources

  • White Papers
  • Videos
  • Training
  • Live Webinars
  • PQ Resources
  • Support

Company

  • About Us
  • Contact
  • Careers
  • Newsletter
  • Product Registration
  • Terms & Conditions
800 N Main St, Mt Crawford, VA 22841 | Toll Free 800.296.4120 | Fax 540.432.9430
© 2026 Power Monitors, Inc.